(English) Public Structures

By | tammikuu 12th, 2017|pr|

Tämä teksti on valitettavasti saatavilla vain kielillä: Amerikanenglanti.

Kommentit pois päältä artikkelissa (English) Public Structures

(English) Architectural

By | tammikuu 12th, 2017|pr|

Tämä teksti on valitettavasti saatavilla vain kielillä: Amerikanenglanti.

Kommentit pois päältä artikkelissa (English) Architectural

(English) Smart-Bus Hybrid Integration Link with IP – SB-RSIP-DN GTIN(UPC-EAN): 0610696254061

By | tammikuu 6th, 2017|Yleinen|

(English) DIN-Rail Mount, with BUS, RS232, 485 & IP/UDP Bridged Converter, can send up to 1980 Strings, & Can receive up to 99 ASCII and/or HEX strings, work in all Baud Rates, 2-way Functionality for integration and status Update (Good For User Input Applications)

Kommentit pois päältä artikkelissa (English) Smart-Bus Hybrid Integration Link with IP – SB-RSIP-DN GTIN(UPC-EAN): 0610696254061

(English) S-BUS to RS232 Module For ”Nuvo” Integration – SB-RS232N-DN GTIN(UPC-EAN): 0610696254078

By | tammikuu 6th, 2017|Yleinen|

(English) DIN-Rail Mount, Preloaded Protocol (Direct Nuvo Music 2-way integration interface for G series with M3 server, T2 tuner, and Nuvo RIPS, WIPS Ipod Dock)

Kommentit pois päältä artikkelissa (English) S-BUS to RS232 Module For ”Nuvo” Integration – SB-RS232N-DN GTIN(UPC-EAN): 0610696254078

(English) SMS Module Remote Control and Monitoring – SB-SMS-FL GTIN (UPC-EAN): 0610696255266

By | tammikuu 6th, 2017|Yleinen|

(English) SBUS enabled SMS Module Capable of Sending and Recieving Multiple Messages to/from Multiple Numbers for Performance and Monitoring of Activity, Mood, Energy, Lighting ++. Great for Security Monitoring. Built in Sensor Ports, Audio Speaker Port, Microphone Plug Port to enable Communication Between Base and Remote Phones from anywhere in the world. (Soon to Add Gate GSM Function)

Kommentit pois päältä artikkelissa (English) SMS Module Remote Control and Monitoring – SB-SMS-FL GTIN (UPC-EAN): 0610696255266

(English) Super Mini I/O – SB-Mini4I/O-UN GTIN(UPC-EAN): 0610696253972

By | tammikuu 6th, 2017|Yleinen|

(English) Simple 4 Input Analogue Sensor Good for (Dry Contacts of Digital Sensors or As inputs for Analogue Temperature Sensor Inputs) 4 Outputs 0-10V That Can be used for (Valves, Speed control, LED Etc.) with Built in 32 Logics and triggers. Smart-BUS Enabled

Kommentit pois päältä artikkelissa (English) Super Mini I/O – SB-Mini4I/O-UN GTIN(UPC-EAN): 0610696253972

(English) Pump Control and Monitoring Module – SB-Pump-DN GTIN(UPC-EAN): 0610696253958

By | tammikuu 6th, 2017|Yleinen|

(English) Din rail Mount, Fully Bus Enabled 5 Status Dry inputs (Trip, Run, Off, Auto, Manual), Logic, 2 Output Relays 20A, for (Run, Auto)

Kommentit pois päältä artikkelissa (English) Pump Control and Monitoring Module – SB-Pump-DN GTIN(UPC-EAN): 0610696253958

(English) S-BUS Enabled Energy Global Genset – SB-GENSet-UN GTIN(UPC-EAN): 0610696254290

By | tammikuu 6th, 2017|Yleinen|

(English) Diesel Engine Monitoring Gensen, To monitor and Trigger or dissable Ingition, RPM, Tank, Temp, Power Metering and other. Both RS-232 and IP Enabled with Http. CAN BUS Ready

Kommentit pois päältä artikkelissa (English) S-BUS Enabled Energy Global Genset – SB-GENSet-UN GTIN(UPC-EAN): 0610696254290

(English) Solonoid Valve 1″ – OE-Svalve1

By | tammikuu 6th, 2017|Yleinen|

(English) 12VDC Driven Valve to Help Preserve Water in Case of any probable Leakage inside Bath fixtures like: (Basin or Tub Faucet Mixer, Toilet Flush gasket ++). This Device require connection to Relay Channel and Availability of Occupancy Sensing Device to Trigger the Relay output (on/Off accordingly). The Valve can Also be used for control of Water Floor Heating System together with HVAC2 Module for Cold Countries

Kommentit pois päältä artikkelissa (English) Solonoid Valve 1″ – OE-Svalve1

(English) Water Leak Detector – OE-WLeak-UN

By | tammikuu 6th, 2017|Yleinen|

(English) Simple Analogue Detector and Digital Driver to connect to 12VDC Rated NO/NC of (4Z Module SB-4Z-UN). Max Wire Length = 18cm. Operating Current: 200mA, Standby=1mA

Kommentit pois päältä artikkelissa (English) Water Leak Detector – OE-WLeak-UN